Multiport block valves with main line open Print E-mail
Multiport block valves with main line open
 
for example T-Valve or ZDL-Valve
 
 
 
 

           Description                                                               

P&ID

Illustration
(actuators and other options are included
in some of the illustrations)

1.1)
T-Valve or ZDL-Valve                                        

1x point of use valve port

Recommended installation:
S3 down illustration right side:
T-valve with U-bend added for
distribution loop installation

 

 
 
     

1.15)
MA 31

1x point of use valve port

Recommended installation:
S3 horizontal

 

 
 
     

1.2)
ML 3/1

1x point of use valve port  with
integrated directional flow 90°
to the main line

Recommended installation:
S3 down

 

                             
 
     

1.3)
MY 3/1

1x point of use valve port with
Y main line inlet and outlet. Thus
the inlet and outlet dimension
of the main line is reduced and
can meet the centerline dimensions of an ASME BPE 180° U-bend.

Recommended installation:
S3 down

 

                           
     

1.4)
MZ  4/2

1x point of use valve port
1x integral loop sample valve port can be opposite positioned as showed on the picture or sidewise.

Recommended installation:
S3 down

 

                  
                    
     

1.45)
MT 4/2

1x point of use valve port
1x integral loop sample valve port
Two parallel one-sided orientated
valve actuators.

Recommended installation:
S3 down

 

                      
 
     

1.55)
MFE 4/2

2x point of use valve ports
The number of valve ports is variable

Recommended installation:
S2 vertical down

 

                  
 
     

1.6)
MX 4/2

1x point of use valve port
1x integral sample purge valve
valve port below the weir can be
opposite positioned as showed on
the picture or sidewise.

Recommended installation:
S3 vertical down

 

                  
               
     

1.7)
MW 5/3

2x point  of use valve port
1x integral loop sample valve port
1x integral sample purge valve port below the weir.

Recommended installation:
S4 down

 

                 
            
     

1.8) MF 6/4
1x point of use valve port with integrated
directional flow 90° to the main line
1.8 A)
2x integral sample purge valve port below the weir
1.8 B)
1x integral loop sample purge valve port
2x integral sample purge valve port below the weir

Recommended installation:
S5 and S3 down, S4 horizontal

 

       
                       
     

1.9)
MT 6/4

4x point of use valve ports
The number of valve ports is variable

Recommended installation:
S1 and S2 horizontal
S3...S6 vertical down or vertical up orientation.
S1 and S2 can be vertical if tube outlets S3 to S6 are positioned to the lowest point of valve pocket

 

              
         
     

1.10)
MX 12/10

10x point of use valve ports
The number of valve ports is variable


Recommended installation:
S1 and S2 horizontal
S3 to S10 horizontal or vertical up
orientation.
S1 and S2 can be vertical if tube outlets
S3 to S10 are positioned to the lowest point  of valve pocket

 

        
                
     
     

  For further information, please contact us